Accurately calculate thermal expansion and contraction, and optimise the design of joints and expansion solutions; the SS360 lock-seam plate connector incorporates a sliding plate that can move along the bearing’s slide groove to mitigate thermal stress.
A movement allowance should be provided between the flashing and the roof to accommodate longitudinal thermal expansion and contraction, thereby preventing cracking and leakage in the flashing.